On a basic Interface calibration certificate what does the mV/V figure represent?

The most basic of the Interface load cell calibration certificates gives a single mV/V value but this figure has real value.

Many manufacturers only provide a Terminal value or in Interface terms RATED OUTPUT i.e. the measured signal value at full rated load, but the figure provided by Interface is the Static Error Band Output (SEB OUTPUT) which is a calculated best-fit value.

The SEB OUTPUT requires a minimum of 4 measurements at 3 points these being zero, 50% range ascending 100% range and 50% range descending.

For SSM & SM S-beam style units the provided value is that for tension measurements while the MB & MBI units are provided with compression values.

For more information contact us directly or via info@interface.uk.com